SDG Impact Detail

Sustainable Development Goals

14.4.1 Water discharge guidelines and standards

Metric: Water sensitive waste disposal

Have water quality standards and guidelines for water discharges (to uphold water quality in order to protect ecosystems, wildlife, and human health and welfare) 

Prince of Songkla University (PSU) has established water-quality standards, wastewater treatment requirements and operational guidelines for wastewater discharge to prevent pollution and protect aquatic and terrestrial ecosystems, wildlife, human health and community welfare.

PSU’s approach combines a university-wide water-management policy, compliance with national effluent standards, wastewater-treatment infrastructure, defined operating procedures, regular water-quality monitoring and the reuse of appropriately treated wastewater.

University Water Management Policy

PSU’s Water Management Policy requires wastewater generated from University buildings and operations to be properly treated before discharge.

Under the policy:

  • wastewater-treatment systems in University buildings must be maintained in effective operating condition;

  • new and renovated buildings must incorporate preliminary wastewater treatment before wastewater enters the University sewer system;

  • wastewater discharged from University facilities must comply with applicable water-quality standards;

  • wastewater from University units must be continuously monitored and controlled; and

  • appropriately treated wastewater is encouraged to be reused, including for irrigation where suitable.

These requirements are intended to prevent inadequately treated wastewater from entering public waterways and surrounding aquatic and terrestrial environments.


Water Discharge Standards

PSU requires wastewater discharge to comply with applicable Thai national effluent standards.

The University follows the Ministry of Natural Resources and Environment Notification on Effluent Standards for Certain Types and Sizes of Buildings B.E. 2567 (2024), which establishes wastewater-discharge limits for educational institutions, residential buildings, commercial premises and healthcare facilities.

Depending on building type and size, key parameters include:

Water-quality parameterApplicable discharge criterion*
pH5.5–9.0
Biochemical Oxygen Demand (BOD)≤20–40 mg/L
Total Suspended Solids (TSS)≤30–50 mg/L
Total Dissolved Solids (TDS)≤1,000–1,300 mg/L
Sulfide≤1.0 mg/L
Total Kjeldahl Nitrogen (TKN)≤35–40 mg/L
Oil and Grease≤20 mg/L

*The applicable limit depends on building category and size in accordance with the national regulation.

Wastewater Treatment at Hat Yai Campus

At PSU Hat Yai Campus, wastewater from campus activities is directed to a centralised wastewater-treatment system before discharge to public waterways.

The upgraded treatment system increased capacity from approximately 500 to 1,000 cubic metres per day and incorporates:

  • screening and preliminary collection;

  • a sump;

  • an aerated lagoon operated as a Sequencing Batch Reactor (SBR);

  • an oxidation pond;

  • aeration and biological treatment;

  • pH control; and

  • water-quality monitoring equipment.

The SBR operates on a defined six-hour treatment cycle consisting of:

  • four hours of aeration;

  • one hour of settling; and

  • one hour of resting/decanting.

The oxidation pond provides additional treatment and oxygenation before final discharge.


Water-Quality Monitoring and Verification

PSU carries out systematic monitoring of wastewater quality rather than relying solely on policy requirements.

At Hat Yai Campus, wastewater samples were collected monthly from October 2023 to March 2025 at both the influent and final outlet before discharge to the public drainage system.

Samples were analysed by PSU’s Central Scientific Instrument Center.

Operational monitoring included:

ParameterOperational criterion
pH5–9
Total Dissolved Solids (TDS)≤500 mg/L
Suspended Solids (SS)≤30 mg/L
Oil and Grease≤20 mg/L
Sulfide≤1.0 mg/L
Total Kjeldahl Nitrogen (TKN)≤35 mg/L
Biochemical Oxygen Demand (BOD)≤20 mg/L
Chemical Oxygen Demand (COD)Monitored

Following improvements to the treatment system, the average BOD concentration in treated wastewater was 16.01 mg/L during academic semesters and 15.54 mg/L during semester breaks.

The treatment system achieved approximately:

  • 73.63% BOD removal efficiency; and

  • 37.01% TKN removal efficiency.

These monitoring results demonstrate the University’s use of measurable water-quality criteria to verify treatment performance before wastewater is discharged.

Operational Controls at Campus Level

PSU also applies operational wastewater-management guidelines at campus level.

For example, PSU Pattani Campus requires:

  • wastewater treatment at all discharge points;

  • functioning wastewater-treatment systems;

  • verification of treated-water quality against legal standards;

  • regular maintenance of grease traps and treatment systems;

  • appropriate management of sludge, oils and food residues; and

  • inspection and preventive measures to avoid wastewater leakage.

These operational requirements help ensure that wastewater is controlled from the source through treatment and final discharge.

Protecting Ecosystems and Human Health

Through its university-wide policy, national water-quality standards, treatment infrastructure, operational guidelines and regular monitoring, PSU maintains a systematic approach to wastewater management.

The University’s water-discharge controls are designed to prevent untreated or inadequately treated wastewater from entering receiving waters, reduce pollutant loads and protect aquatic ecosystems, terrestrial environments, wildlife, human health and the welfare of surrounding communities.